top of page

PRO 150 

1 EQUIPMENT SPECIFICATIONS

The PRO line equipment is manufactured with a carbon steel frame, sandblasted and painted in orange with an anticorrosive epoxy base, and the panel sheet metal is made of stainless steel. It features fans to ensure proper cooling, quick-connect terminals, and a compensated socket of type K, following the ANSI MC96.1 and ASTM E230 color standards.

(*) Outras tensões de entrada mediante consulta

Image1.png.

Trifásico
380/440V

228/197A

Triple Cooling
System

(L) 848 mm
(C) 848 mm
(A) 1397 mm

Orange paint on the frame and stainless steel sheet metal

620 kg

3-year warranty subject to

scheduled maintenance

1.1 Alarm and Disarm System

The equipment allows for configuration so that when there is a temperature difference between the process value (PV) and the set point (SP), the visual and audible alarm is triggered. Additionally, the disarm time can be configured in case the issue is not resolved. In this case, the power transformer of the equipment will be turned off, while the control and recording panel remains powered on.

Note: The factory default configuration for the temperature difference is 50°C, and the waiting time for disarm is 5 minutes. These parameters can be configured.

1.2 Operational Safety

The equipment has a control panel connection independent of the power supply, allowing the entire thermal cycle configuration to be performed without the main transformer being powered on. The equipment includes a main circuit breaker, fast-blow fuses for each circuit, a residual current device (RCD), and a glass fuse for each rear socket.

1.2.1  Break Down System

If the core reaches a temperature of 150°C, for safety, the breakdown system shuts down the main transformer, preventing overheating, fires, and irreversible damage. The control and logging panel remains powered on.

1.3 Temperature Recorder

Image1.png.
DATA SHEET TECNOTRAT PRO 150 - REV02_edi
  • 1 Six-channel recorder

  • 5.7" LCD display

  • Multifunctional panel keys

  • Measurement accuracy: ±0.15% of reading (TC, RTD)

  • Waterproof and dustproof (IP-65 compliant)

  • CF cards up to 4 GB with adapter

  • Large (400 MB) internal memory

You can use the keys to switch to any of the operation screens. The operational states of memory sampling, alarms, key lock, computation, and other conditions are displayed graphically.

Idiom: Mandarin, English, German, French, Italian, Spanish, Portuguese, Russian, Korean, and Japanese.

DATA SHEET TECNOTRAT PRO 150 - REV02.jpg.

DIGITAL DISPLAY:

In addition to displaying measurements digitally, it shows the channel/TAG, industrial units, and alarm status.

Note: The internal thermocouple extension cables are 16 AWG with electrostatic shielding and a drain wire to reduce fluctuations and noise in the thermocouple signal.

1.4 Triple Cooling System

DATA SHEET TECNOTRAT PRO 150 - REV02.jpg.
Image1.png.
  • Increases power by 30%

  • Extends equipment lifespan

  • Allows continuous operation without pauses

  • Reduces energy consumption

High Duty: 24 hours a day, 7 days a week, 365 days a year

2 TECNOTRAT WARRANTY

The equipment warranty is 36 months, provided that the maintenance and inspections are carried out by Tecnotrat and according to the preventive maintenance schedule in the manual.

Image1.png.

REVISÕES + GARANTIA DE 3 ANOS

 

= ECONOMIA

3 QUANTITIES OF ACCESSORIES AND SUPPLIES:

The wiring diagram below illustrates that each channel consists of 1 temperature controller, 1 thermocouple interconnected via an extension cable of the same alloy, and 3 resistors of 80 VAC and 3.6 kW, interconnected by triple branch cables and double cables, as shown in the schematic drawing.

DATA SHEET TECNOTRAT PRO 150 - REV02.jpg.

Note: We offer multiple accessories such as thermocouples, Capacitive Discharge Thermocouple Mounting Unit (TAU), Paperless Recorder (available upon request), general connection cables, thermal insulation blankets, insulation covers, etc.

4 COMPARISON BETWEEN TECNOTRAT EQUIPMENT LINES:

Image1.png.

Operational

Safety

Programmed

Drive System

Estructure
100% Inox

MultiTap 40V
(3 x 1,3kW)

Customization

Ventilation

System

Warranty

Operational

Safety

Number of
channels

Recorder

Power

(kVA)

Exit

Input voltage (V)
Three-phase

Transformer winding

Insulation class

Break Down

System

High Duty

doesn't have

Chart Recorder

Digital Recorder (optional chart recorder)

Up to 4 resistors

60V - 3 resistors of 2.7 kW

60V - 3 resistors of 2.7 kW or
80V - 3 resistors of 3.6 kW

Aluminum winding

High-purity electrolytic copper winding (99.9%)

Class F insulation (up to 155°C)

Class F insulation (up to 155°C)

Conventional with fan in exhaust mode, with front and rear louvers

Triple Cooling System. A unique triple forced ventilation system that guarantees up to 30% more power.

36-month warranty, subject to scheduled maintenance

Complete, with exclusive buttons to turn the machine on and off with electrical protection,
main circuit breaker, fuses for each electrical circuit, residual current circuit breaker,
exclusive fuse for each output socket.

Standard item

Forced

ventilation

3 months

Convencional