PRO 300
1 ESPECIFICAÇÕES DO EQUIPAMENTO
PRO line equipment is manufactured with a carbon steel chassis, shot-blasted and painted in orange with an anti-corrosive epoxy primer. The panel casing is made of stainless steel, and the equipment includes fans to ensure proper cooling. The terminals feature quick-connect clamps, and it has a type K compensated socket following the ANSI MC96.1 and ASTM E230 color standard.

(Image for illustrative purposes only, subject to change without prior notice.)
(*) Other input voltages available upon request

1.1 Alarm and Disarm System
The equipment allows configuration so that when there is a temperature difference between the process value (PV) and the setpoint (SP), the audio-visual alarm is triggered. It can also be configured with a disarm time in case the issue is not resolved. In this scenario, the equipment's power transformer will be turned off, while the control and recording panel remains operational.
Note: The factory default setting for the temperature difference is 50°C, and the disarm delay time is 5 minutes. These parameters can be adjusted.
1.2.1 Break Down System
If the core reaches a temperature of 150°C, for safety reasons, the breakdown system shuts down the main transformer to prevent overheating, fires, and irreversible damage. The control and recording panel remains operational.
1.3 Temperature Recorder


-
02 Recorders, consisting of 1 piece with 12 channels and 1 piece with 12 channels;
-
5.7" LCD Display;
-
Multifunctional panel keys;
-
Measurement accuracy: ±0.15% of reading (TC, RTD);
-
Waterproof and dustproof (IP-65 compliant);
-
CF cards up to 4 GB with adapter;
-
Large internal memory (400 MB).
Você pode usar as teclas para alternar para qualquer uma das telas de operação. Os estados operacionais de amostragem de memória, alarmes, bloqueio de chave, computação e outras condições são exibidos graficamente.
Idiom: Chinese, English, German, French, Italian, Spanish, Portuguese, Russian, Korean, and Japanese.

DIGITAL DISPLAY:
Além de exibir as medições digitalmente, ele exibe o canal / TAG, unidades industriais e status de alarme.
Note: The internal extension cables for the thermocouple are 16 AWG with electrostatic shielding and drain wire to reduce fluctuations and noise in the thermocouple signal.
1.4 Triple Cooling System
We are the only national manufacturers to develop the Triple Cooling System, providing focused and forced cooling 100% of the time while the equipment is powered on.


-
Increases power by 30%
-
Extends equipment lifespan
-
Allows continuous operation without pause
-
Reduces energy consumption
High Duty: 24h por dia, 7 dias por semana, 365 dias por ano
2 TECHNATRAT WARRANTY
The equipment warranty is 36 months, subject to the completion of maintenance and inspections performed by Tecnotrat and in accordance with the preventive maintenance schedule outlined in the manual.

REVIEWS
+
3-YEAR WARRANTY = SAVINGS
3 QUANTITATIVO DE ACESSORIOS E INSUMOS:
The wiring diagram below illustrates that for each channel, it is composed of 01 temperature controller, 01 thermocouple interconnected through an extension cable of the same material, 03 80 VAC resistors of 3.6 kW, interconnected by triple-branch cables and double cables, as shown in the schematic diagram.

4 COMPARATIVO ENTRE AS LINHAS DE EQUIPAMENTOS TECNOTRAT:

Conventional with fan in exhaust mode,
featuring front and rear air vents.
Triple Cooling System. A unique triple
forced ventilation system that guarantees up to 30%
more power.
Forced
ventilation
Class F insulation (up to 155°C)
Aluminum winding
60V - 3 resistors of 2.7 kW
Up to 4 resistors
Graphical Chart
Recorder
Doesn't have
number of
channels
Recorder
Power
(kVA)
Exit
Input Voltage (V)
Three-phase
Transformer
Winding
Insulation
Class
Break Down
System
High Duty
Digital Recorder (optional graphical chart)
60V - 3 resistors of 2,7 kW ou
80V - 3 resistors of 3,6 kW
High-purity electrolytic copper winding 99.9%
Class F insulation (up to 155°C)
Sistema de
ventilação
Warranty
Operational
Safety
3 months
36-month warranty, subject to scheduled maintenance reviews.
Convencional
Complete, with exclusive buttons to turn the machine on and off with electrical protection, main circuit breaker, fuses for each electrical circuit, residual current circuit breaker, and a dedicated fuse for each output socket.
Operational
Safety
Optional items
Scheduled
Drive
System
Estrutura
100% Inox
MultiTap 40V
(3 x 1,3kW)
Standard item
Customization