top of page

PRO 75

1.0 EQUIPMENT SPECIFICATIONS

PRO line equipment is manufactured with a carbon steel frame structure, sandblasted and painted in orange with an anticorrosive epoxy base, and panel plates made of stainless steel. It is equipped with fans to ensure proper cooling. The terminals are quick-connect type, and the compensated socket is of type K, in accordance with the ANSI MC96.1 and ASTM E230 color standards.

DATA SHEET TECNOTRAT PRO 75 - REV02.jpg.

(For illustrative purposes only,

subject to change without prior notice)

Image1.png.

1.1 Alarm and Disarm System

The equipment allows configuration so that, when there is a temperature difference between the process value (PV) and the programmed value (SP), the audible-visual alarm is triggered. The disarm time can also be configured in case the issue is not resolved. In this case, the equipment's power transformer will be turned off, while the control and recording panel remains powered on.

Note: The factory setting for the temperature difference is 50°C, and the waiting time for disarm is 5 minutes. These parameters can be configured.

1.2 Operational Security

The equipment features independent control panel connection from the power supply, allowing the entire thermal cycle configuration to be carried out without the main transformer being powered on. The equipment is equipped with a main circuit breaker, quick-blow fuses for each circuit, a differential circuit breaker (DR), and a glass fuse for each rear socket.

1.2.1  Break Down System

If the core reaches a temperature of 150°C, for safety, the breakdown system shuts down the main transformer, preventing overheating, fires, and irreversible damage. The control and recording panel remains powered on.

1.3 Temperature Recorder

DATA SHEET TECNOTRAT PLUS 75 - REV02.jpg.
Image1.png.
  • 01 6-channel Recorder;

  • 5.7 LCD Display;

  • Multifunctional panel keys;

  • Measurement accuracy: ± 0.15% of reading (TC, RTD);

  • Waterproof and dustproof (IP-65 compliant);

  • CF cards up to 4 GB with adapter;

  • Large internal memory (400 MB).

You can use the keys to switch to any of the operation screens. The operational states for memory sampling, alarms, key lock, computation, and other conditions are displayed graphically.

Idiom: Mandarin, English, German, French, Italian, Spanish, Portuguese, Russian, Korean, and Japanese.

DATA SHEET TECNOTRAT PRO 75 - REV02.jpg.

Digital Display

In addition to displaying the measurements digitally, it shows the channel/TAG, industrial units, and alarm status.

Note: The internal thermocouple extension cables are 16 AWG with electrostatic shielding and drain wire, designed to reduce fluctuations and noise in the thermocouple signal.

1.4 Triple Cooling System

Somos os únicos fabricantes nacionais a desenvolver o Triple Cooling System Refrigeração focada e forçada 100% do tempo em que o equipamento estiver com a potência ligada.

DATA SHEET TECNOTRAT PRO 75 - REV02.jpg.
Image1.png.
  • Increases power by 30%

  • Extends the equipment's lifespan

  • Allows continuous operation without breaks

  • Reduces energy consumption

High Duty: 24 hours a day, 7 days a week, 365 days a year.

2 TECHNICAL WARRANTY

The equipment warranty is 36 months, provided that maintenance and inspections are carried out by Tecnotrat and within the preventive maintenance schedule outlined in the manual.

Image1.png.

REVIEWS
+
3-YEAR WARRANTY = SAVINGS

3 ACCESSORIES AND CONSUMABLES QUANTITY:

The wiring diagram below illustrates that each channel consists of 01 temperature controller, 01 thermocouple connected through an extension cable of the same alloy, 03 resistances of 80 VAC, 3.6 kW, interconnected by triple branch cables and double cables, as shown in the schematic drawing.

DATA SHEET TECNOTRAT PRO 75 - REV02.jpg.

Note: We offer multiple accessories such as thermocouples, Capacitive Discharge Thermocouple Mounting Unit (TAU), Paperless Recorder (upon request), general connection cables, thermal insulation blankets, insulation covers, etc.

4 COMPARISON BETWEEN TECNOTRAT EQUIPMENT LINES:

Image1.png.

Operational

Safety

Scheduled

Activation

System

Estructure 100% Inox

MultiTap 40V
(3 x 1,3kW)

Customization

Ventilation

System

Warranty 

Operational

Safety

Number of

channels

Registrador

Power
(kVA)

Exit

Input Voltage (V)
Three-phase

Transformer

Winding

Insulation

Class

System
Break Down

High Duty

Doesn't have 

Chart

Recorder

Digital Recorder (optional chart recorder)

Up to 4 resistances

60V - 3 resistances of 2.7 kW

60V - 3 resistances of 2,7 kW ou
80V - 3 resistances of 3,6 kW

Aluminum winding

High-purity 99.9% electrolytic copper winding

Class F insulation (up to 155°C)

Class F insulation (up to 155°C)

Conventional with an exhaust fan, featuring front and rear vents.

Triple Cooling System. A unique triple forced ventilation system that ensures up to 30% more power.

36-month warranty, subject to scheduled maintenance.

Complete, with exclusive buttons for turning the machine on and off with electrical protection, main circuit breaker, fuses for each electrical circuit, residual differential circuit breaker, and a dedicated fuse for each output socket.

Standard item

Forced

ventilation

3 months

Conventional

bottom of page