STANDARD 10
1 EQUIPMENT SPECIFICATIONS
The equipment in the STANDARD line is recommended for preheating services and can be used for heat treatment with the use of a temperature recorder.

(For illustrative purposes only, subject to change without prior notice.)

1.1 Alarm System
When there is a temperature difference between the actual and the programmed values, the alarm is triggered, and the process can be stopped using the "SET" button. The equipment has 3 alarms that can be set by the user.
1.2 Operational Safety
The equipment features a main switch, an integrated protection system against overheating, overload, and short circuit at the output, overvoltage or undervoltage at the input, and an automatic main power supply circuit.
Note: The equipment has a visual indicator for inverter overheating or undervoltage/overvoltage in the power supply.
1.3 Built-in recorder:
The recorder allows continuous recording of temperature, both set-point and actual, output voltage, and system errors.
The recording starts automatically when the heating cycle begins. The recorded data can be transferred via USB to a PC (ASCII file). If the saved file is in CSV format, it can be opened directly with Excel. The data file is identified by the heating date and time, as well as a unique registration number for each series.
2 Rack Interconnection
The Tecnotrat STANDARD 10 heating system can be connected in parallel via an interconnection (umbilical) cable to operate either jointly or independently, depending on the need. It is possible to set up a rack with 3 to 6 machines, as shown in the figures below.

Note: The rack is sold separately in modules of 3 units each.
3 QUANTITY OF ACCESSORIES AND SUPPLIES:
The wiring diagram below illustrates that each channel consists of 01 temperature controller, 01 thermocouple interconnected through an extension cable of the same alloy. The Tecnotrat STANDARD 10 equipment allows the use of up to 04 resistances of 60 VAC, 2.7 kW, in parallel, interconnected by quadruple branch cables and double cables, as shown in the schematic drawing.

Note: We offer multiple accessories such as thermocouples, Capacitive Discharge Thermocouple Mounting Units (TAU), Paperless Recorders (upon request), general connection cables, thermal insulation blankets, insulation covers, etc.
4 COMPARISON BETWEEN TECNOTRAT EQUIPMENT LINES:

Operational
Safety
Scheduled
Drive System
Estructure
100% Inox
Ventilation
System
Warranty
Operational
Safety
Number
of channels
Recorder
Power
(kVA)
Exit
Input Voltage (V)
Three-phase
Transformer
winding
Insulation
class
Break Down
System
High Duty
Doesn't have
Chart Recorder
Digital Recorder (Optional Chart Recorder)
Up to 4 resistances
60V - 3 resistances of 2.7 kW
60V - 3 resistances of 2.7 kW or
80V - 3 resistances of 3.6 kW
Aluminum winding
Electrolytic copper winding with high purity of 99.9%
Class F insulation (up to 155°C)
Class F insulation (up to 155°C)
Conventional with fan in exhaust mode, with front and rear louvers.
Triple Cooling System. Unique triple forced ventilation system that guarantees up to 30% more power.
36-month warranty, subject to scheduled maintenance.
Complete, with exclusive buttons to turn the machine on and off with electrical protection, main circuit breaker, fuses for each electrical circuit, residual current circuit breaker, and a dedicated fuse for each output socket.
Ventilação
forçada
3 months
Conventional
Standard item
Customization
MultiTap 40V
(3 x 1,3kW)
optional items