STANDARD 75
1 EQUIPMENT SPECIFICATIONS
STANDARD line equipment is manufactured with a carbon steel chassis, sandblasted and painted in orange with an anti-corrosive epoxy primer, and panel plating in carbon steel painted black. It includes fans to ensure proper cooling, quick-connect terminals, and a type K compensated socket following the ANSI MC96.1 and ASTM E230 color standards.


1.1 Alarm and Shutdown System
The equipment allows configuration so that when there is a temperature difference between the process value (PV) and the programmed value (SP), the audio-visual alarm is triggered. It is also possible to set a shutdown time if the issue is not resolved. In this case, the equipment's power transformer will be turned off, while the control and recording panel will remain on.
Note: The factory setting for the temperature difference is 50°C, and the waiting time for shutdown is 5 minutes. These parameters can be adjusted.
1.2 Operational Safety
The equipment features a button to power the control panel independently of the main power transformer. This allows the entire thermal cycle configuration to be carried out safely without the main transformer being energized. The equipment is equipped with a main circuit breaker, fuses, and a Residual Current Device (RCD).
1.3 Standalone Recorder (Optional)
Tecnotrat equipment features a thermocouple signal branching socket that allows the connection of standalone temperature recorders, to be used in processes requiring graphical recording

2 TECNOTRAT WARRANTY
The equipment warranty is 36 months, provided that maintenance and inspections are carried out by Tecnotrat and within the preventive maintenance schedule outlined in the manual.

REVIEWS +
3-YEAR WARRANTY = SAVINGS
3 QUANTITY OF ACCESSORIES AND SUPPLIES:
The wiring diagram below illustrates that each channel consists of 01 temperature controller, 01 thermocouple connected through an extension cable of the same alloy, 03 resistances of 60 VAC, 2.7 kW, interconnected by triple branch cables and double cables, as shown in the schematic drawing.

4 COMPARISON BETWEEN TECNOTRAT EQUIPMENT LINES:

Operational Safety
Programmed
Activation System
Estructure
100% Inox
MultiTap 40V
(3 x 1,3kW)
Customization
Ventilation
System
Warranty
Operational
Safety
Number of
channels
Recorder
Power
(kVA)
Exit
Input Voltage (V)
Three-phase
Transformer
winding
Insulation class
Break Down
System
High Duty
Doesn't have
Chart
Recorder
Digital Recorder (Optional Chart Recorder)
up to 4 resistance
60V - 3 resistors of 2.7 kW
60V – 3 resistances of 2.7 kW or
80V – 3 resistances of 3.6 kW
Aluminum winding
High-purity 99.9% electrolytic copper winding
Class F insulation (up to 155°C)
Class F insulation (up to 155°C)
Conventional with fan in exhaust mode, with front and rear louvers
Triple Cooling System.Unique triple forced ventilation system that guarantees up to 30% more power
36-month warranty, subject to scheduled maintenance
Complete, with exclusive buttons to turn the machine on and off with electrical protection, main circuit breaker, fuses for each electrical circuit, residual current circuit breaker, and a dedicated fuse for each output socket.
Standard item
Forced
ventilation
3 months
Conventional
Optional items